Microsoft declares its underwater data center test was a success

The <em>Northern Isles</em>, a 12-rack / 864-server underwater data center pod, is winched off the seafloor in this picture after its two-year trial deployment.
Magnify / The Northern Isles, a 12-rack / 864-server underwater information heart pod, is winched off the seafloor on this image after its two-year trial deployment.

Microsoft retrieved a 40-foot-long, 12-rack, self-contained underwater information heart from its seafloor house offshore from the Orkney Islands previous this summer season.

The retrieval of the Northern Isles started the general segment of Microsoft’s Undertaking Natick analysis initiative, exploring the concept that of deploying sealed server pods simply offshore primary inhabitants facilities in its place for normal onshore information facilities.

Why put servers underwater?

Undertaking Natick has been underway for a number of years; we lined the two-month trial deployment of Leona Philpot, the corporate’s first underwater server pod, in 2016, and the deployment of the newly retrieved Orkney Isles pod in 2018.

The possible downside of sealed underwater “information facilities” is plain—they should be extraordinarily dependable, since they may be able to’t be serviced regularly. There’s a moderately much less intuitive, counterbalancing benefit, in fact—they do not have any pesky people wandering round inside of them, doubtlessly dislodging cables, unplugging issues, or in a different way injecting chaos.

There are extra benefits to those miniature underwater information facilities. Seafloor-based pods do not require pricey industrial actual property, they usually get just about loose cooling from the encircling lots of seawater.

The logistic benefit could also be much more vital than the cooling or speedy monetary one. It takes important time and specialised effort to obtain and increase industrial actual property for a standard information heart in a big town—construction a sealed pod and deploying it at the seafloor close by must be significantly more practical and quicker.

Retrieving the Northern Isles

The Northern Isles underwater information heart pod was once constructed by means of Naval Crew (a protection and renewable marine power contractor) and is in the community supported by means of Inexperienced Marine, an Orkney Island-based marine engineering and operations company. It spent two years underneath the water on the Ecu Marine Power Centre, the place tidal currents top at 9mph and typhoon waves achieve 60 ft or extra.

Each deployment and retrieval of the Northern Isles wanted in particular calm climate and a complete day of cautious paintings involving robots and winches between the pontoons of a gantry barge. Throughout the pod’s two years underwater, it got a coating of algae and barnacles, in addition to cantaloupe-sized sea anemones colonizing sheltered nooks in its base.

Examining the consequences

The entire 12-rack, 864-server data center is slid from the hull of the <em>Northern Isles</em> as a unit, after preliminary <em>in situ</em> analysis.
Magnify / All the 12-rack, 864-server information heart is slid from the hull of the Northern Isles as a unit, after initial in situ research.

Jonathan Banks

Earlier than sliding the 12-rack, 864-server information heart unit out of the pod’s hull, Microsoft’s researchers took inside air samples from the still-sealed pod for research in Redmond. “We left it full of dry nitrogen, so the surroundings is lovely benign in there,” Microsoft Particular Initiatives researcher Spencer Fowers mentioned. Research of the air after the two-year deployment will give the group further details about cable and different apparatus outgassing.

The servers deployed aboard the Northern Isles failed at a fee roughly one-eighth what professionals would be expecting from the similar servers in a conventional, human-serviced information heart over the similar duration. Microsoft’s group hypothesizes that that is in part because of the sealed, inert nitrogen environment the pod was once pressurized with sooner than deployment.

With none oxygen for human technicians to respire or over the top humidity for his or her convenience, there are fewer alternatives for chemical corruption of elements. Loss of bumping and jostling by means of those self same human operators most probably additionally contributed to the servers’ strangely low failure fee.

Sustainability and potency

Windmills like this one provide 100 percent of the electricity grid which services residents of the Orkney Islands—a cable from that grid also supplied power to the <em>Northern Isles</em>, in addition to tidal turbines and wave energy converters.
Magnify / Windmills like this one supply 100 % of the electrical energy grid which products and services citizens of the Orkney Islands—a cable from that grid additionally equipped chronic to the Northern Isles, along with tidal generators and wave power converters.

Scott Eklund

The a success two-year deployment of the Northern Isles demonstrates the feasibility of greener, extra sustainable chronic projects for information facilities, above and past the potency of cooling the information heart itself.

One reason why the Undertaking Natick group deployed the Northern Isles to the Orkney Islands is as a result of its grid is provided 100 % by means of wind, sun, and experimental inexperienced applied sciences beneath building on the Ecu Marine Power Centre itself. “We now have been in a position to run truly neatly on what maximum land-based information facilities believe an unreliable grid,” Fowers mentioned.

Ben Cutler, a mission supervisor for Undertaking Natick, believes that co-located offshore wind farms may just viably chronic manufacturing deployments very similar to the Northern Isles. Even mild wind prerequisites would most probably be sufficient to chronic the pods, with a shore powerline bundled in with the pod’s fiber-optic information cabling as a final hotel. Cutler additionally notes that the seawater cooling for such deployments is not only inexpensive than conventional cooling—it leaves freshwater assets important to people and natural world untapped.